A Novel Architecture Based On A Conducting Polymer And Calixarene Derivative: İts Synthesis And Biosensor Construction

  • Yazar/lar GÖKOĞLAN, Tuğba Ceren
    SÖYLEMEZ, Saniye
    KESİK, Melis
    ÜNAY, Hande
    SAYIN, Serkan
    YILDIZ, Hüseyin Bekir
    ÇIRPAN, Ali
    TOPPARE, Levent
  • Yayın Türü Makale
  • Yayın Tarihi 2015
  • DOI Numarası 10.1039/c5ra03933a
  • Yayıncı Royal Society of Chemistry
  • Tek Biçim Adres http://hdl.handle.net/20.500.12498/3107

In this study, a novel amperometric glucose biosensor based on a selenium comprising conducting polymer and calixarene was developed. Firstly, poly(2-(2-octyldodecyl)-4,7-di(selenoph-2-yl)-2H-benzo[d][1,2,3]triazole), poly((SBTz)) was electrodeposited onto a graphite electrode by an electropolymerization technique. Then, a newly synthesized calixarene and gold nanoparticle (AuNP) mixture was used for the improvement of biosensor characteristics. GOx, as a model enzyme was immobilized on the modified electrode surface. The constructed surface serves as a sufficient immobilization platform for the detection of glucose. Calixarenes and their derivatives may be a favouring agent for enzyme immobilization due to their specific configurations. Moreover, through the covalent binding between the carboxylic groups of the calixarenes and amino groups of the biomolecule, effective enzyme immobilization can be achieved while protecting the well-ordered structure of the enzyme molecule. Amperometric detection was carried out following oxygen consumption at -0.7 V vs. the Ag reference electrode in phosphate buffer (50 mM, pH 6.5). The proposed biosensor showed a linear amperometric response for glucose within a concentration range of 0.005 to 0.5 mM (LOD: 0.004 mM). Kappm and sensitivity were calculated as 0.025 mM and 102 μA mM-1 cm-2, respectively. Scanning Electron Microscopy (SEM) was used to investigate the surface morphologies of successive modifications. Finally, the constructed biosensor was tested successfully to detect glucose in beverage samples. © The Royal Society of Chemistry 20153.

  • Koleksiyonlar
Erişime Açık
Görüntülenme
5
22.03.2024 tarihinden bu yana
İndirme
1
22.03.2024 tarihinden bu yana
Son Erişim Tarihi
19 Nisan 2024 15:04
Google Kontrol
Tıklayınız
Tam Metin
Tam Metin İndirmek için tıklayın Ön izleme
Detaylı Görünüm
Eser Adı
(dc.title)
A Novel Architecture Based On A Conducting Polymer And Calixarene Derivative: İts Synthesis And Biosensor Construction
Yayın Türü
(dc.type)
Makale
Yazar/lar
(dc.contributor.author)
GÖKOĞLAN, Tuğba Ceren
Yazar/lar
(dc.contributor.author)
SÖYLEMEZ, Saniye
Yazar/lar
(dc.contributor.author)
KESİK, Melis
Yazar/lar
(dc.contributor.author)
ÜNAY, Hande
Yazar/lar
(dc.contributor.author)
SAYIN, Serkan
Yazar/lar
(dc.contributor.author)
YILDIZ, Hüseyin Bekir
Yazar/lar
(dc.contributor.author)
ÇIRPAN, Ali
Yazar/lar
(dc.contributor.author)
TOPPARE, Levent
DOI Numarası
(dc.identifier.doi)
10.1039/c5ra03933a
Atıf Dizini
(dc.source.database)
Scopus
Yayıncı
(dc.publisher)
Royal Society of Chemistry
Yayın Tarihi
(dc.date.issued)
2015
Kayıt Giriş Tarihi
(dc.date.accessioned)
2020-08-07T13:00:40Z
Açık Erişim tarihi
(dc.date.available)
2020-08-07T13:00:40Z
Kaynak
(dc.source)
RSC Advances
ISSN
(dc.identifier.issn)
20462069 (ISSN)
Özet
(dc.description.abstract)
In this study, a novel amperometric glucose biosensor based on a selenium comprising conducting polymer and calixarene was developed. Firstly, poly(2-(2-octyldodecyl)-4,7-di(selenoph-2-yl)-2H-benzo[d][1,2,3]triazole), poly((SBTz)) was electrodeposited onto a graphite electrode by an electropolymerization technique. Then, a newly synthesized calixarene and gold nanoparticle (AuNP) mixture was used for the improvement of biosensor characteristics. GOx, as a model enzyme was immobilized on the modified electrode surface. The constructed surface serves as a sufficient immobilization platform for the detection of glucose. Calixarenes and their derivatives may be a favouring agent for enzyme immobilization due to their specific configurations. Moreover, through the covalent binding between the carboxylic groups of the calixarenes and amino groups of the biomolecule, effective enzyme immobilization can be achieved while protecting the well-ordered structure of the enzyme molecule. Amperometric detection was carried out following oxygen consumption at -0.7 V vs. the Ag reference electrode in phosphate buffer (50 mM, pH 6.5). The proposed biosensor showed a linear amperometric response for glucose within a concentration range of 0.005 to 0.5 mM (LOD: 0.004 mM). Kappm and sensitivity were calculated as 0.025 mM and 102 μA mM-1 cm-2, respectively. Scanning Electron Microscopy (SEM) was used to investigate the surface morphologies of successive modifications. Finally, the constructed biosensor was tested successfully to detect glucose in beverage samples. © The Royal Society of Chemistry 20153.
Yayın Dili
(dc.language.iso)
en
Tek Biçim Adres
(dc.identifier.uri)
http://hdl.handle.net/20.500.12498/3107
Analizler
Yayın Görüntülenme
Yayın Görüntülenme
Erişilen ülkeler
Erişilen şehirler
6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve cerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms