[email protected] Karatay
    • Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   [email protected] Karatay
  • ARAŞTIRMA ÇIKTILARI
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
  •   [email protected] Karatay
  • ARAŞTIRMA ÇIKTILARI
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

A novel architecture based on a conducting polymer and calixarene derivative: Its synthesis and biosensor construction

Gokoglan, T.C.; Soylemez, S.; Kesik, M.; Unay, H.; Sayin, S.; Yildiz, H.B.; Cirpan, A.; Toppare, L.
  • BibTex
  • EndNote (RIS)
Loading
Thumbnail
Date
2015
URI
http://hdl.handle.net/20.500.12498/3107
Metadata
Show full item record
Abstract
In this study, a novel amperometric glucose biosensor based on a selenium comprising conducting polymer and calixarene was developed. Firstly, poly(2-(2-octyldodecyl)-4,7-di(selenoph-2-yl)-2H-benzo[d][1,2,3]triazole), poly((SBTz)) was electrodeposited onto a graphite electrode by an electropolymerization technique. Then, a newly synthesized calixarene and gold nanoparticle (AuNP) mixture was used for the improvement of biosensor characteristics. GOx, as a model enzyme was immobilized on the modiified electrode surface. The constructed surface serves as a sufficient immobilization platform for the detection of glucose. Calixarenes and their derivatives may be a favouring agent for enzyme immobilization due to their specific configurations. Moreover, through the covalent binding between the carboxylic groups of the calixarenes and amino groups of the biomolecule, effective enzyme immobilization can be achieved while protecting the well-ordered structure of the enzyme molecule. Amperometric detection was carried out following oxygen consumption at -0.7 V vs. the Ag reference electrode in phosphate buffer (50 mM, pH 6.5). The proposed biosensor showed a linear amperometric response for glucose within a concentration range of 0.005 to 0.5 mM (LOD: 0.004 mM). Kappm and sensitivity were calculated as 0.025 mM and 102 μA mM-1 cm-2, respectively. Scanning Electron Microscopy (SEM) was used to investigate the surface morphologies of successive modifications. Finally, the constructed biosensor was tested successfully to detect glucose in beverage samples. © The Royal Society of Chemistry 20153....  Show more  Show less
Item type
Article
Collections
  • Scopus İndeksli Yayınlar Koleksiyonu [475]

- KTO Karatay Kutuphanesi
- KTO Karatay Universitesi
- Contact Us / Send Feedback
DSpace software
Gemini
 

 

Browse

Communities & CollectionsBy Issue DateAuthorsTitlesSubjectsBy lcAuthorBy TypeBy publisherBy languageBy rightsThis CollectionBy Issue DateAuthorsTitlesSubjectsBy lcAuthorBy TypeBy publisherBy languageBy rights

My Account

LoginRegister

- KTO Karatay Kutuphanesi
- KTO Karatay Universitesi
- Contact Us / Send Feedback
DSpace software
Gemini