Compact Muon Solenoid (CMS) experiment has been preparing for Upgrade-2 and High Luminosity-Large Hadron Collider (HL-LHC) projects during Long Shutdown 2 (LS2) by replacing and enhancing electronics and the components of its detector. The Upgrade-2 project will implement high intensities in the collisions, which results in a highly integrated luminosity of about 2500 f b−1 at the heart of the detector. Moreover, the experiment will gather more data with the HL-LHC, which enables an additional integrated luminosity by a factor of 10 beyond the current luminosity value of the Large Hadron Collider (LHC) after 2027. Higher luminosity values bring about higher temperature onto electronics of the detector, therefore controlling and monitoring the temperature around the detector environment under challenging operating conditions plays a crucial role. This temperature monitoring has been fulfilled by the Programmable Logic Controller (PLC) up to this point in time. However, a new and optimum monitoring system is made essential because PLC-based monitoring is more expensive and takes much more place. The work presented in this Tez addresses the above-mentioned issues and proposes a novel temperature monitoring system using embedded systems. In this approach, we developed a Massive Temperature Monitoring System (MTRS), including sensor choices, designing readout circuitry, hardware and software implementations, and optimizing the issues to have arisen, as well as providing communication between MTRS and Detector Control System (DCS) via Open Platform Communications Unified Architecture (OPC UA) server. This dissertation discusses the reasons why the MTRS is essential for the future upgrades of the detector and furnishes the ways of embedded-based approach.

Erişime Açık
Görüntülenme
274
22.03.2024 tarihinden bu yana
İndirme
1
22.03.2024 tarihinden bu yana
Son Erişim Tarihi
10 Ekim 2024 11:53
Google Kontrol
Tıklayınız
Tam Metin
Tam Metin İndirmek için tıklayın Ön izleme
Detaylı Görünüm
Eser Adı
(dc.title)
Innovative Standalone Massive Channel Temperature Monitoring System For Cms Detector
Yayın Türü
(dc.type)
Tez
Yazar/lar
(dc.contributor.author)
TEKİŞ, Hatice
Atıf Dizini
(dc.source.database)
Diğer
Konu Başlıkları
(dc.subject)
OPC-UA
Konu Başlıkları
(dc.subject)
Network Programming
Konu Başlıkları
(dc.subject)
Embedded Systems
Konu Başlıkları
(dc.subject)
Internet of Things
Konu Başlıkları
(dc.subject)
Integrated Circuit Design
Yayıncı
(dc.publisher)
KTO Karatay Üniversitesi
Tez Danışmanı
(dc.contributor.advisor)
YUMUŞAK, Semih
Yayın Tarihi
(dc.date.issued)
2021
Kayıt Giriş Tarihi
(dc.date.accessioned)
2022-01-04T06:34:12Z
Açık Erişim tarihi
(dc.date.available)
2022-01-04T06:34:12Z
Tez Türü
(dc.type.thesis)
Yüksek Lisans
Özet
(dc.description.abstract)
Compact Muon Solenoid (CMS) experiment has been preparing for Upgrade-2 and High Luminosity-Large Hadron Collider (HL-LHC) projects during Long Shutdown 2 (LS2) by replacing and enhancing electronics and the components of its detector. The Upgrade-2 project will implement high intensities in the collisions, which results in a highly integrated luminosity of about 2500 f b−1 at the heart of the detector. Moreover, the experiment will gather more data with the HL-LHC, which enables an additional integrated luminosity by a factor of 10 beyond the current luminosity value of the Large Hadron Collider (LHC) after 2027. Higher luminosity values bring about higher temperature onto electronics of the detector, therefore controlling and monitoring the temperature around the detector environment under challenging operating conditions plays a crucial role. This temperature monitoring has been fulfilled by the Programmable Logic Controller (PLC) up to this point in time. However, a new and optimum monitoring system is made essential because PLC-based monitoring is more expensive and takes much more place. The work presented in this Tez addresses the above-mentioned issues and proposes a novel temperature monitoring system using embedded systems. In this approach, we developed a Massive Temperature Monitoring System (MTRS), including sensor choices, designing readout circuitry, hardware and software implementations, and optimizing the issues to have arisen, as well as providing communication between MTRS and Detector Control System (DCS) via Open Platform Communications Unified Architecture (OPC UA) server. This dissertation discusses the reasons why the MTRS is essential for the future upgrades of the detector and furnishes the ways of embedded-based approach.
Yayın Dili
(dc.language.iso)
eng
Tek Biçim Adres
(dc.identifier.uri)
http://hdl.handle.net/20.500.12498/5173
Analizler
Yayın Görüntülenme
Yayın Görüntülenme
Erişilen ülkeler
Erişilen şehirler
6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve cerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms