Detaylı Arama

İptal
Bulunan: 4 Adet 0.001 sn
- Eklemek veya çıkarmak istediğiniz kriterleriniz için 'Dahil' / 'Hariç' seçeneğini kullanabilirsiniz. Sorgu satırları birbirine 'VE' bağlacı ile bağlıdır.
- İptal tuşuna basarak normal aramaya dönebilirsiniz.
Filtreler
Erişime Açık

Investigation of the Effect of Processor Type on Daily Implant Use Time in Cochlear Implant Users

EŞDOĞAN, Ayşegül | AYKUL YAĞCIOĞLU, Ayşenur | KARAKÜLÜK, N.İrem | ÖZBAL BATUK, Merve

Introduction: In individuals with cochlear implants (CI), continuous wear of the hearing devices is crucial for maintaining auditory input and supporting auditory development. It is recommended that cochlear implant processors be used throughout waking hours. Modern cochlear implant systems provide clinicians with data on the usage of sound processors by CI users through a process known as "data logging." This data logging enables the automatic and objective measurement of CI usage based on average daily usage hours. Previous studies examining data records of patients with CIs have revealed si ...Daha fazlası

Erişime Açık

Examining the Relationship Between Ecap Thresholds with Thr Level and Mcl in Cochlear Implant Users: Preliminary Results

AYKUL YAĞCIOĞLU, Ayşenur | ÇİÇEK ÇINAR, Betül | KARAKÜLÜK, N.İrem | EŞDOĞAN, Ayşegül

Introduction: Electrically Evoked Compound Action Potential (ECAP) objectively evaluates the synchronous response from auditory nerve fiber using the telemetry function of the cochlear implant. In addition, this measurement helps to determine the threshold of hearing (THR) and maximum comfort levels (MCL). In various studies examining the relationship between ECAP thresholds and the stimulation levels used to program the speech processor, the correlation between ECAP thresholds with THR and MCL levels varied. In this study, it was aimed to compare the ECAP thresholds in MEDEL cochlear implant ...Daha fazlası

Erişime Açık

Comparison of Immunoassay and Liquid Chromatography-Tandem Mass Spectrometry Methods in the Measurement of Serum Androstenedione Levels.

YÜCEL, Kamile | ABUŞOĞLU, Sedat | ÜNLÜ, Ali

Abstract BACKGROUND: Recent reports have described inherent problems with androgen immunoassays compared with mass spectrometry analyses. In this study, a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed according to CLSI rules. The developed method was compared with two immunoassay methods, the enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (RIA). METHODS: After liquid-liquid extraction, a Shimadzu Prominence LC unit coupled to an ABSCIEX API 3200 mass spectrometer with atmospheric pressure chemical ionization was used to quantify serum andros ...Daha fazlası

Erişime Açık

The Effect Of Serum And Follicular Fluid Hypoxia İnducible Factor 1α On İnvitro Fertilization Outcomes İn Patients With Polycystic Ovary Syndrome

YÜCEL, Kamile

Abstract Objective: To investigate serum and follicular fluid (FF) HIF-1α levels in nonobese, nonhyperandrogenic patients with polycystic ovary syndrome (PCOS) undergoing in vitro fertilization (IVF), in addition to IVF outcomes. Materials and Methods: A prospective sequential cross-sectional study carried at a Research and Education Hospital. In total, 160 patients undergoing IVF treatment were included in the study: 80 patients diagnosed with PCOS according to the Rotterdam criteria (group I, study) and 80 patients with the etiology of male factor infertility (group II, control). Results: Th ...Daha fazlası

6698 sayılı Kişisel Verilerin Korunması Kanunu kapsamında yükümlülüklerimiz ve cerez politikamız hakkında bilgi sahibi olmak için alttaki bağlantıyı kullanabilirsiniz.

creativecommons
Bu site altında yer alan tüm kaynaklar Creative Commons Alıntı-GayriTicari-Türetilemez 4.0 Uluslararası Lisansı ile lisanslanmıştır.
Platforms